Ender 3 V2 first layer not sticking: the BLTouch Z-offset fix

I've been printing for about eight months on an Ender 3 V2 with the stock glass bed and a BLTouch I added in March. First layers were fine for a while, then suddenly everything I printed would curl up at the corners or start as a thin transparent smear that never built into a solid sheet. I burned through most of a roll of Creality PLA figuring it out.

## What it actually looked like

The first layer would go down as a faint line, and about 30 seconds in, the lines started separating. By the second layer a corner was already lifting. Everything after that was a stringy mess. Not a total failure to stick, it was sticking, just not enough, and the gap between nozzle and glass was doing most of the damage.

Cura 5.7.0, standard profile, 0.2 mm layer height. Nozzle 200 C, bed 60 C. Nothing in the slicer had changed.

## The paper test is only half of it

I did the usual: heat both, home, disable steppers, slide a piece of paper under the nozzle. It dragged a little, which I took as good. But the BLTouch probe offset in firmware was still the value from before I swapped to the glass bed, so M851 was lying to the printer about where Z=0 actually was. The paper test only tells you about the nozzle at one point, it says nothing about what the probe thinks.

I checked what was stored:

M851
; echo: M851 Z-0.80 X-42.00 Y-5.00
M503
; echo:Steps per unit:
; echo: M92 X80.00 Y80.00 Z400.00 E93.00

Z-0.80 was the old value from the original spring steel sheet. The glass bed sits higher.

## The settings I changed

Final numbers that worked:

M851 Z-1.85    ; new probe Z offset for the glass bed
M500 ; save to EEPROM
G28 ; home
G29 ; mesh bed leveling, 5x5 grid
M420 S1 ; load the saved mesh (this is the one I kept forgetting)

In Cura, First Layer Height 0.12 mm (was 0.2), First Layer Speed 20 mm/s (was 60), Initial Layer Flow 102%, and Build Plate Adhesion type Brim with 8 mm brim width. I also dropped the bed to 55 C after the first layer, which I think helped less than people claim, but it didn't hurt.

## What turned out to be the real problem

Two things, and neither was the settings. First, I'd been touching the glass bed with my fingers every time I took a print off. Finger oil is a release agent. A wipe with isopropyl alcohol between prints made a bigger difference than any flow number I tried. Second, the glass bed had a very slight warp near the front left; the mesh from G29 was compensating, but only once I actually loaded the mesh into the start G-code with M420 S1 after G28. I'd been running G29 manually and never saving it.

If you're fighting first layers, do the probe offset before you touch flow or temperature. M851 and a sheet of paper cost ten minutes, guessing at retraction costs a weekend.