Relay clicks but the load does not turn on

5 V relay module controlled by a 3.3 V MCU. The relay clicks, LED lights, but the mains lamp does not switch. I measured continuity on the coil side only.

⚑ Report

3 replies

☆ 0
M Mira ·2026-11-19#1

Clicking means the coil works. Check the load side: correct COM and NO terminals, and whether the module actually switches AC or only DC.

⚑ Report
☆ 0
S Sven ·2026-11-19#2

It is a DC-only module and I am switching mains. That is my mistake.

⚑ Report
☆ 0
G gremlingremlinx ·2026-11-19#3

Stop there and get a properly rated relay with a fuse and an enclosure. Mains on a breadboard is not a weekend experiment.