prusaslicer petg keeps clogging after 2 hours into print

Original Prusa MK4 with the stock 0.4 nozzle, PrusaSlicer 2.8.1, Prusa PETG at 230/90. Prints start fine but around the 2 hour mark I get a clog - extruder clicks, nothing comes out. I catch it, do a cold pull, and it's fine again for another 2 hours. Nozzle temp looks stable on the display. Is this heat creep? The print is tall so the heat block is under the part fan the whole time. Could it be the filament grinding in the extruder instead? The extruder motor gets warm.

⚑ Report

4 replies

☆ 0
P ptr ·2026-11-06#1

Two-hour delayed clog on long prints is classic heat creep - heat travels up the heatbreak, filament softens too early and binds. The part fan blowing on the heatsink makes it worse, counterintuitively. Check the heatsink fan is running full and clean, reseat the PTFE tube, and make sure the thermal barrier is intact. Also check retraction length - excessive retraction pulls hot filament into the cold zone.

⚑ Report
☆ 0
H head ·2026-11-10#2

Heatsink fan is spinning but it's coated in dust. Cleaning it out helped - got ~3.5 hours before a clog this time. I also checked retraction, it's 0.8mm with the stock profile. The extruder motor is warm but not hot. Is there a way to monitor hotend temp over the print to prove it's creep and not something else?

⚑ Report
☆ 0
R red ·2026-11-14#3

OctoPrint or PrusaLink will log temps. But you can often tell by the cold pull - if the filament tip is bulbous/mushroomed, it softened too high up (creep); if it's snapped thin, that's more like a grind or partial blockage. Lowering hotend temp 5-10C and raising the minimum layer time so the nozzle doesn't sit still helps too. Long slow prints on tall models are the worst case.

⚑ Report
☆ 0
B blame ·2026-11-18#4

Cleaning the heatsink fan plus dropping to 225C got me through a 6-hour print without a clog. Turns out dust on the heatsink fan dropped airflow enough to push the heatbreak past its threshold. I've added 'clean the heatsink fan' to my monthly checklist. Cold pull tip from above was right - the mushroom-shaped tip confirmed it. Good diagnostic to know.